If your fireplace is sending smoke into the room, let it go out, air the space and do not light it again until you understand why. Indoor smoke may come from a cold or blocked flue, insufficient replacement air, wind around the roofline or alterations made during renovation. Blocking vents, building a bigger fire or improvising at the chimney top usually makes matters worse. The immediate priority is to move people away from smoke, ventilate and separate simple observations from work that needs a competent technician.
Contents
Stop using it if smoke returns persistently, if there is a strong combustion smell beyond the fireplace area, or if anyone has headache, dizziness, nausea, unusual drowsiness, shortness of breath or confusion. Carbon monoxide has no colour or smell, so a room that merely seems “poorly ventilated” may need a prompt response.
Take everyone outside or into clean air, open doors and windows only if you can do so without exposing yourself to smoke, and call 112 if there are symptoms or suspected poisoning. Do not go back in to test the appliance. The Portuguese Health Directorate guidance on carbon monoxide and generators lists these warning signs and says to leave immediately until professionals consider the area safe.
You should also stop where there are new cracks in the firebox, loose parts, black staining around the opening, falling soot, rainwater entering through the chimney, or a sudden change after roof work, window replacement or the installation of extract fans.
Start by noting when the smoke appears. If it happens only during the first minutes and improves as the flue warms, cold, heavy air may be sitting inside the chimney. If it gets worse when the kitchen extractor, an extract fan or a vented tumble dryer is running, the home may be extracting more air than it can replace.
If the fireplace smokes mainly on windy days, the cause may be the chimney terminal, its height above the roof or nearby obstacles creating turbulence. If the problem follows rain, look for signs of water entry, failed mortar or deposits falling into the fireplace. Do not climb onto the roof to check: external inspection needs safe access and appropriate protection.
An open fire or closed wood-burning insert needs air for combustion and for combustion gases to rise through the flue. In renovated flats, tighter windows, well-sealed doors and mechanical extraction can alter the balance that once allowed the chimney to work. Opening a nearby window for a few minutes can be a diagnostic test only; it is not a permanent solution and cannot replace correctly planned air supply.
The Portuguese Health Directorate advises providing effective extraction for combustion gases and ventilating while activities release moisture and pollutants, including the use of combustion appliances. Read the DGS general recommendations for indoor air before deciding to cover a grille or alter ventilation.
Avoid these shortcuts:
When replacing windows, also consider how reveals and air-tightness details will work; this guide to window reveals during replacement in Lisbon helps place that detail in context without confusing draught-proofing with eliminating fresh-air renewal.

Soot build-up, nests, leaves, an unsuitable terminal, damaged liner or a reduced section are common reasons for weak draught. In houses, the chimney can also become partly sheltered by a neighbouring building, parapet or mature trees. In older Lisbon buildings, several flues may share the same chimney stack; connecting an appliance to an unconfirmed route is unsafe.
A cold flue can also struggle to establish draught. Burning wet wood, lighting an oversized fire at once, or burning rubbish, plastic-coated cardboard and treated timber increases smoke and deposits. The answer is not to add more fuel: use suitable dry fuel, light gradually and confirm that the flue is clean and continuous.
Arrange an inspection when you do not know the flue route, the fireplace has been unused for years, roof work has taken place or there are signs of water. The technician should explain the appliance condition, continuity of the exhaust route, cleaning needs and the installation’s limits before proposing alterations.
A one-off smoky start, with wet wood and a cold flue, may improve when fuel and lighting method are corrected. Repeated smoke return, wind-related backdraught, smells in distant rooms, staining around the chimney or physical symptoms point to an issue that should not be treated as a routine operating habit.
There is a clear point to call a professional: any suspected blockage, crack, poor connection, chimney leak, roof alteration, gas connection or need to alter the flue. Do not push rigid rods into it, remove roof elements or apply foam, sealant or mortar inside the flue without a diagnosis.
Before winter, DGS advises checking home-heating equipment, cleaning the chimney when necessary and keeping the home aired. See the DGS cold-weather guidance for homes; it also states that charcoal braziers must never be used indoors.
Treat the next use as an organised check, not a series of repeated attempts. First, confirm cleaning and chimney condition. Then review whether the home’s ventilation, extractors or windows have changed. Finally, set an operating routine: dry suitable fuel, gradual lighting, doors and controls in the manufacturer’s stated position, and no competing extraction while starting the fire.
If you are renovating the living room, do not choose a heating system only for the appearance of the fireplace insert. Consider thermostat location, occupancy schedules and the relationship between the fireplace, main heating and ventilation. Our guide to thermostat settings and schedules in a Lisbon flat can help coordinate other systems without relying on the fireplace to solve all comfort needs.
A sound decision records four items: the cleaning date, who checked the installation, changes made to the home and symptoms that justify calling for help again.
Key takeaways
If the fireplace is part of a renovation or a ventilation correction, gather photographs, dates and the changes already made to the home. Obra Lisboa can place the work within the renovation plan, coordinating chimney condition with windows, extraction and finishes before walls or ceilings are closed.
Sources and further reading
Editorial image; it does not depict an Obra Lisboa project.
Privacidade e controlo
Usamos cookies essenciais para o funcionamento do site. Com a sua autorização, podemos também medir a utilização e os resultados dos anúncios. A medição de publicidade com a OpenAI usa referências técnicas, sem enviar nome, email, telefone ou mensagem do pedido. Pode aceitar, rejeitar ou gerir cada categoria. Consulte a Política de Privacidade e a Política de Cookies.
Necessários para segurança, navegação e memorização da sua escolha.
Ajuda a medir utilização e desempenho sem enviar dados de contacto.
Permite medir campanhas, incluindo anúncios no ChatGPT. Com a OpenAI, a medição usa referências técnicas para associar pedidos aos anúncios, sem enviar nome, email, telefone ou mensagem. É opcional e pode ser desativada a qualquer momento.