Insulating hot-water pipes is worthwhile when a renovation opens walls, ceilings or floors: it reduces heat lost along the route and can help hot water reach the tap sooner. Yet hastily fitted foam will not solve pipework that is too long, poorly arranged or impossible to isolate for repairs. In a Lisbon flat, the right decision starts by drawing the route between the water heater and the kitchen, shower and basins before any service boxing is closed.
Contents
Pipework carries hot water through colder parts of the home: suspended ceilings, cupboards, service risers, external walls or storage areas. The longer the route and the longer the wait, the more water is run off before it reaches a useful temperature. Insulation slows heat loss, but it does not shorten a network that takes unnecessary detours.
In Lisbon, where the January mean temperature at the Lisboa/Geofísico station is 11.8 °C, an unprotected section in a lightly heated area can cool quickly between uses. See the IPMA Lisbon climate normals for the local seasonal context.
There are three useful signs during the works:
The first remedy is to place the heat source closer to the heaviest users, or to split the network sensibly. Insulation comes after that decision.
Ask the installer to mark hot-water pipe runs, supply branches, any recirculation returns and pipework crossing unheated spaces on the drawings. These are the points where insulation should be continuous, including bends, joints and wall penetrations, without crushing the material.
Portuguese Ordinance no. 138-I/2021 sets requirements for insulating fluid-transport networks. For pipes carrying fluid at 40 to 65 °C with an external diameter up to 35 mm, its table gives 20 mm as a reference; for secondary systems without recirculation, it allows no less than 10 mm. Requirements depend on diameter, temperature and insulation conductivity, so a thickness should never be copied without checking the actual system.
Do not leave out:
A metal clamp directly over insulation can compress it and create a weak point. The fixing detail matters as much as the visible pipe run.
| Route | Priority | Detail to check |
|---|---|---|
| Inside a wall or suspended ceiling | Continuous insulation before closing up | Bends, joints and installation photographs |
| Technical cupboard or cold area | Reduce heat loss and contact with cold surfaces | Access to valves and maintenance |
| Outside | Extra insulation and protection | UV protection, mechanical protection and water entry |
| Long route to the shower | Review the layout before increasing thickness | Distance, branches and waiting time |
Start with daily use, not with the easiest place to hide the equipment. A main bathroom far from the water heater can turn every shower into repeated waiting. At design stage, mark the points of use and compare two or three possible routes.
If you are planning a domestic hot-water heat pump, allow proper space for condensate drainage, ventilation and maintenance. Moving it far away simply to conceal it often increases pipe length and complexity. Efficient hot-water use also depends on settings and habits, as explained in the ADENE Save Energy Together action plan.

The material must suit the operating temperature, location and installation method. Common renovation choices include flexible elastomeric sleeves, polyethylene foam and mineral or rigid products for particular situations. The decision should not be based solely on appearance or cost per metre.
Ask for the technical data sheet and check the declared thermal conductivity. The regulation uses a reference conductivity to define minimum thicknesses; if the product performs differently, the required thickness changes too. In exposed locations, insulation needs a suitable outer protection. In concealed locations, it must withstand installation without being cut, crushed or soaked by a leak.
Avoid two recurring mistakes: insulating only straight runs while leaving bends and fittings bare; and using tape as a cure for large gaps at joints. Tape may finish a correctly selected system, but it does not replace a properly fitted sleeve.
Where the renovation also includes radiator heating, review how heat is distributed through rooms. Curtains and furniture in front of emitters reduce effectiveness; ADENE’s Save heating costs in winter guide highlights this issue. See also how to keep radiators under windows working efficiently.
Recirculation keeps hot water available through a return circuit, but it uses energy to make up for losses and may require a pump, controls, valves and maintenance. In a compact flat, a short, well-insulated route is often the simpler answer. In larger houses or very long systems, the choice should compare comfort, consumption, schedules and build quality.
Do not treat recirculation as a permanently switched-on feature. Where it is needed, it should have appropriate control: timer settings, scheduling or demand activation as designed. A constantly active return in a poorly insulated network turns pipework into an unintended small radiator inside walls and ceilings.
It is also important to keep subjects separate. Insulating hot-water pipes does not replace a whole-home ventilation strategy. If the work is already opening service zones, assess whether there is scope for heat-recovery ventilation in a flat, without improvising mixed air-duct and plumbing access routes.
Complete a final check with the plumber and, where relevant, the person coordinating the renovation. This is not the moment to guess where every pipe ended up.
Call a qualified professional when changing the hot-water appliance, introducing recirculation, working with gas, electrical connections, structural elements or any sign of a leak. Do not use expanding foam to hide pipework that vibrates, drips or has not been tested. Finishes should start only after the installation has been confirmed.
A well-coordinated renovation uses opened-up walls to resolve what will remain invisible for years. Before ordering finishes or closing a suspended ceiling, ask Obra Lisboa to coordinate hot-water routes, technical access and the remaining building services in the renovation plan.
Key takeaways
Opening walls in a kitchen or bathroom? Ask Obra Lisboa for a renovation proposal that coordinates plumbing, equipment, maintenance access and finishes before work starts.
Sources and further reading
Editorial image; it does not depict an Obra Lisboa project.
Privacidade e controlo
Usamos cookies essenciais para o funcionamento do site. Com a sua autorização, podemos também medir a utilização e os resultados dos anúncios. A medição de publicidade com a OpenAI usa referências técnicas, sem enviar nome, email, telefone ou mensagem do pedido. Pode aceitar, rejeitar ou gerir cada categoria. Consulte a Política de Privacidade e a Política de Cookies.
Necessários para segurança, navegação e memorização da sua escolha.
Ajuda a medir utilização e desempenho sem enviar dados de contacto.
Permite medir campanhas, incluindo anúncios no ChatGPT. Com a OpenAI, a medição usa referências técnicas para associar pedidos aos anúncios, sem enviar nome, email, telefone ou mensagem. É opcional e pode ser desativada a qualquer momento.