Heat-recovery ventilation in a flat: when it works

Structural Work
·
Joinery
·
Decoration
·
Consultancy
·
3D Design
·
Interior Design
·
Construction
·
Full Renovations
·
Architecture
·
Engineering
·
Demolition
·
Painting and Finishes
·
Electrical and Plumbing
·
Wall and Floor Finishes
Discreet heat-recovery ventilation unit on the wall of a renovated Lisbon bedroom.

A decentralised heat-recovery ventilation unit can improve the air in a bedroom or living room without running ducts throughout the flat, but it only works when it is part of a clear supply-and-extract air strategy. In a Lisbon renovation, it is worth considering in rooms closed for many hours, on noisy façades, or after old leaky windows are replaced with tighter frames. It will not cure water ingress, and it does not replace properly planned extraction from the kitchen and bathroom.

Contents

  1. What a decentralised unit does — and does not do
  2. Which Lisbon flats are good candidates?
  3. Six checks before drilling the wall
  4. How to avoid condensation, draughts and noise
  5. Filters, cleaning and signs the system needs attention
  6. Make the decision before the renovation closes up

What a decentralised unit does — and does not do

This equipment passes through an external wall and uses a fan to renew indoor air. In heat-recovery models, outgoing air transfers part of its energy to incoming air without the two air streams mixing. The aim is to reduce stale-air conditions and limit winter heat loss compared with leaving a window open for long periods.

Two broad principles are common: units that alternate between supply and extract, usually installed in pairs, and continuous-flow units with two air paths. The decision should not begin with a catalogue. It starts with the room, the air route between rooms and the location of the external intake or discharge.

Portuguese rules distinguish natural, mechanical and mixed ventilation, and consider both airflows and heat-recovery efficiency when describing a system. See the technical framework in the Diário da República notice on ventilation systems. Ventilation remains necessary at home because occupants, cooking, cleaning and drying clothes release moisture and pollutants; the Portuguese Health Directorate explains the main indoor-air factors.

A unit in a bedroom does not remove shower steam or cooking fumes. If the bedroom door is always shut and there is no return-air route, the equipment is working against a barrier created by the layout itself.

Which Lisbon flats are good candidates?

It is most relevant where a renovation will make the building envelope tighter, yet does not allow a full duct network. Think of an older two-bedroom flat with bedrooms facing a busy street, a north-facing room that stays cool and closed, or a living room where opening windows early in the day brings in noise and dust.

It can also help where window ventilation relies too heavily on household routines. Even so, do not buy equipment to conceal recurring mould. First establish whether there is a leak, façade water ingress, a thermal bridge or condensation. A damp wall needs diagnosis; increasing ventilation without stopping incoming water may only make the problem less apparent for a while.

In a flat with air conditioning, the distinction matters for another reason: air conditioning controls temperature but does not guarantee fresh-air renewal. Separate those functions before choosing equipment, as explained in Air conditioning does not ventilate your home.

The approach is weak in some situations: a façade where intervention is not possible, an internal bedroom with no external wall, direct exposure to a strong source of outdoor pollution, or a project already allowing ceiling voids and ducts for a properly designed central system. Compare the alternatives before drilling the wall.

A quick comparison for a renovation
ApproachWhere it usually worksKey constraint to check
Window ventilationHomes with quiet façades and attentive occupantsIt depends on routines, outside noise and weather
Decentralised heat-recovery unitA bedroom or living room with an external wall and localised worksFaçade, unit noise, filters and the return-air route
Central mechanical ducted systemDeep renovation with room for ductworkAvailable ceiling height, design coordination and maintenance

Six checks before drilling the wall

  1. Locate the external wall. Confirm thickness, structure, finishes and whether pipes or cables run through the proposed drilling point.
  2. Treat the façade as a common element. An external grille changes the building’s appearance. In a condominium, check the deed, rules and any required decision before ordering.
  3. Choose the right room. Prioritise the most used bedroom or the living room with repeated signs of stale air, condensation or a need to keep windows shut because of noise.
  4. Draw the air route. Fresh air must be able to reach service spaces where it is extracted. Very airtight internal doors may need an undercut or a transfer grille designed without undermining privacy.
  5. Plan power and controls. A socket hidden behind a wardrobe is not suitable for maintenance. Allow access to the unit, filter and isolating switch.
  6. Coordinate curtains, shutters and furniture. A tall headboard, heavy curtain or wardrobe tight against the wall can obstruct airflow and make a sound decision hard to use.

When works include new service routes, technical boxes or changed finishes, mark the point on the interface plan. This helps prevent electrical work, joinery and painting from hiding essential access; see how to set up those sign-offs in Renovation interface map: who signs off each wall before it is closed.

Preparation of a ventilation wall penetration during the renovation of a flat.

How to avoid condensation, draughts and noise

The unit must be fitted with the slope and sealing details specified by its manufacturer so that condensate or rainwater does not sit within the wall penetration. The seal between sleeve, wall and outside finish matters as much as the unit selection: a poorly sealed core hole can create water ingress and a thermal bridge beside the equipment itself.

Ask for the sound performance at the everyday operating speed, rather than only the lowest setting. In a bedroom, continuous noise can lead occupants to switch the system off; a unit that is quiet on paper but poorly isolated from the wall can transmit vibration through masonry.

Check the external air intake as well. Avoid placing it beside an extract discharge, chimney, balcony where smoking occurs, noisy equipment or an area used by neighbours to dry laundry. The Health Directorate notes that indoor-air quality partly depends on outdoor air quality and on indoor sources including cooking, cleaning products and materials. Read the DGS general recommendations for home ventilation.

During a heatwave, do not treat mechanical ventilation as a substitute for external shading, well-managed shutters and night-time airing when outdoors is cooler. Each measure has a different role; combining them without a clear control strategy adds energy use and confusion.

Filters, cleaning and signs the system needs attention

Heat recovery does not mean fit-and-forget. The filter holds particles and collects dust; once clogged, it reduces airflow and may increase noise. Include the filter model, access method, manufacturer’s service interval and a first user handover in the works specification.

A straightforward routine helps:

  • visually check external grilles after street works, dust or strong wind;
  • clean only approved removable parts and never insert objects into the fan;
  • record filter references and replacement dates;
  • test all operating modes before handover;
  • keep door undercuts and transfer grilles between rooms clear.

Call a technician if there is new vibration, a persistent smell, water appearing around the wall, obvious loss of airflow or the electrical circuit trips. Do not cover the external grille with foam, tape or improvised mesh: this can alter performance and trap moisture where it should not remain.

National technical requirements also address fan specific power, airflow rates and equipment characterisation. The Diário da República notice on fan requirements and extract airflows helps frame what should be requested from the professional sizing the system.

Make the decision before the renovation closes up

The sound approach is not to place a unit on every available wall. It is to define which rooms need regular air renewal, how air moves through the flat, where moist air leaves and whether equipment will remain accessible for maintenance.

Before appointing the contractor, ask for a simple drawing showing unit positions, grilles, electrical supply, door transfer routes, filter access and external finish. Confirm whether the proposal affects the façade, whether the condominium must be informed, and whether the kitchen and bathrooms retain adequate extraction. That turns ventilation into a planned part of the renovation rather than an appliance added at the end.

Key takeaways

  • Use decentralised ventilation to address an identified need in a particular room, rather than as an automatic response to any mould.
  • Always plan the route between air supply in bedrooms or living areas and extraction in wet rooms.
  • Check the façade, noise, electrical supply, filter access and wall-penetration sealing before drilling.
  • Address water ingress and thermal bridges at their cause; a fan cannot correct water entering the structure.

If you are planning a Lisbon flat renovation, speak to Obra Lisboa before walls are closed or windows are ordered: coordinated ventilation, electrical, façade and finishing decisions help reserve the right maintenance access from the outset.

Sources and further reading

Editorial image; it does not depict an Obra Lisboa project.

Let's Work Together
·
Let's Work Together
·
Let's Work Together
·
Let's Work Together
·
Let's Work Together
·
Let's Work Together
·
Let's Work Together
·
Let's Work Together
·
Let's Work Together
·
Let's Work Together
·
Let's Work Together
·
Let's Work Together
·
ObraLisboa - Construção e Remodelação de propriedades
let's create
together